Solar photovoltaic power stations are mainly composed of photovoltaic cell arrays, combiner boxes, low-voltage DC cabinets, inverter cabinets, AC low-voltage cabinets, step-up transformers, etc. The high-voltage AC generated is directly integrated into the power grid. In response to the needs of power parameter detection in each link, Ankerui Company has launched the AGF series photovoltaic confluence acquisition device, PZ series DC detection instrument and ACR series power quality analyzer, which are used in combiner boxes, DC cabinets and AC cabinets respectively, and Centralized background monitoring is achieved through the Acrel-3000 V8.0 photovoltaic power generation monitoring system.
In a photovoltaic power generation system, a large number of photovoltaic cell modules are combined in series and parallel to achieve the required voltage and current values, so as to achieve optimal power generation efficiency. The main function of the APV-M series smart photovoltaic combiner box is to combine the input of the photovoltaic cell array, which is used to reduce the connection between the photovoltaic cell array and the inverter, optimize the system structure, and improve reliability and maintainability. While providing the function of converging lightning protection, it also monitors the operating status of photovoltaic panels, current, voltage, power after converging, lightning arrester status, DC circuit breaker status collection, relay contact output and other functions, and has wind speed, temperature, radiation and other functions. Sensor interface functions such as cameras are available for customers to choose. The device comes standard with an RS485 interface, which can upload measured and collected data to the monitoring system.
16-Channel DC Circuits Monitoring
Various Power Supply Option
Optional DO&DI&AI Function
IP65 Protection Level
RS485 Communication
16-Channel DC Circuits Monitoring Paired with AGF-MxxT Multi-circuits Meter Rated Voltage: up to 1000V |
|
Various Power Supply Option AC 85V~265V DC 24V (±10%) DC 300V~880V |
|
Optional DO&DI&AI Function 2 DO Relay Output 3 DI Switch Input 1 AI Analog Input |
|
IP65 Protection Level Dust&Waterproof Suitable for Outdoor&Indoor Circumstances |
Solor PV Power Distribution Monitoring Solution
Practical Application of AGF MxxT in PV Combiner Box
APV Smart Solar PV Combiner Box installed under PV Array
Product Type |
APV-M4XX |
APV-M8XX |
APV-M12XX |
APV-M16XX |
|
Input Channels |
4 |
8 |
12 |
16 |
|
Input Scope |
DC ± 18A |
||||
Response Time |
1s |
||||
Measuring Accuracy |
Grade 0.5 for PV battery measurement, grade 0.2 for the external analog |
||||
RS485 Comm. |
RS485/ModBus-RTU protocol, 4800/9600/19200/38400bps |
||||
Additional Function |
Relay Output |
2 group switches 5A/AC250V(5A/DC 30V) |
|||
Switch Input |
3 groups of external state inputs (optocoupler or dry contact) |
||||
Analog Input |
PT100, DC 0(4)~20mA, DC 0~10V and 24V power supply with the max. current ≤25mA |
||||
Humidity/Temp. |
The working temperature: -25~+60ºC, R.H.: 95%, the worksite does not have the condensed and corrosive gas |
||||
Altitude |
≤3000m |
||||
Insulation Resistance |
≥100MΩ |
||||
Auxiliary Power |
Auxiliary Power : AC85V~265V or DC 300~880V or DC 24V(±10%) |
||||
Case Waterproof Rating |
IP65 |
||||
Weight |
Approx. 30kg |
||||
Volume(W×H×D) |
700×575×220 |
Shape & Cut-out | Type | Function |
FOB Shanghai (USB) |
Option | Module Price(USD) | Option Grop |
|
AGF-M4T |
4 channels DC0-20A photovoltaic confluence detection, 3.5KV Hall isolation, RS485/Modbus-RTU protocol, accuracy 0.5, 0-1000V voltage measurement, 3 groups of external status input (optical coupling or dry contact mode), auxiliary power supply optional DC1000V, DC1500V |
148 |
1.L (liquid crystal display) 2. P2 (auxiliary power supply DC1000V) 3. P3 (auxiliary power supply DC1500V) |
L-29 P2-29 P3-29 |
at will |
AGF-M8T |
8 channels DC0-20A photovoltaic confluence detection, 3.5KV Hall isolation, RS485/ModbusRTU protocol, accuracy 0.5, 0-1000V voltage measurement, 3 groups of external status input (optical coupling or dry contact mode), auxiliary power supply optional DC1000V, DC1500V |
162 |
||||
AGF-M12T |
12 channels DC0-20A photovoltaic confluence detection, 3.5KV Hall isolation, RS485/Modbus-RTU protocol, accuracy 0.5, 0-1000V voltage measurement, 3 groups of external status input (optical coupling or dry contact mode), auxiliary power supply optional DC1000V, DC1500V |
177 |
||||
AGF-M16T |
16 channels DC0-20A photovoltaic confluence detection, 3.5KV Hall isolation, RS485/Modbus-RTU protocol, accuracy 0.5, 0-1000V voltage measurement, 3 groups of external status input (optical coupling or dry contact mode), auxiliary power supply optional DC1000V, DC1500V |
192 |
||||
AGF-M20T |
20 channels DC0-20A photovoltaic confluence detection, 3.5KV Hall isolation, RS485/Modbus-RTU protocol, accuracy 0.5, 0-1000V voltage measurement, 3 groups of external status input (optical coupling or dry contact mode), auxiliary power supply optional DC1000V, DC1500V |
992 |
||||
AGF-M24T |
24 channels DC0-20A photovoltaic confluence detection, 3.5KV Hall isolation, RS485/Modbus-RTU protocol, accuracy 0.5, 0-1000V voltage measurement, 3 groups of external status input (optical coupling or dry contact mode), auxiliary power supply optional DC 1000V, DC1500V |
296 |
||||
|
AGF-AE-D/200 |
Voltage, current, power measurement,RatedVoltage: AC120 V Rated RMS current:AC200A |
133 |
|
|
|
|
ACR10R-DxxTE |
LCD display Single phase multifunction power meter
|
75 |
1. D10:10A,20A, 40A,80A 2. D16:max 120A 3. D24:max 200A
4. D36:max 300A |
D10: 6/piece |
|
ACR1 ORH-DxxTE |
LCD display Single phase multifunction power meter with THDi, THDu and 2-31st harmonic
|
100 |
D16: 12/piece |
|
||
ACR10R-DxxRE |
LCD display Single phase multifunction power meter |
75 |
1. D110: max 1000A 2. D120: max 2000A 3. D140: max 6300A 4. D190: max 20000A |
D110: 145/piece |
|
|
ACR10RH-DxxRE |
LCD display Single phase multifunction power meter with THDi, THDu and 2-31 st harmonic |
100 |
D120: 175/piece |
|
||
|
ACR10R-DxxTE4 |
LCD display Three phase multifunction power meter |
190 |
D24: 22/piece |
|
|
ACR10RH-DxxTE4 |
LCD display Three phase multifunction power meter with THDi, THDu and 2-31 st harmonic |
220 |
|
D36: 37/piece |
|
|
ACR10R-DxxRE4 |
LCD display Three phase multifunction power meter |
190 |
1. D110: max 1000A 2. D120: max 2000A 3. D140: max 6300A 4. D190: max 20000A |
DUO: 205/piece |
|
|
ACR10RH-DxxRE4 |
LCD display Three phase multifunction power meter with THDi, THDu and 2-31 st harmonic |
220 |
D190: 265/piece |
|
||
DJSF1352-RN |
DC voltage, current, power measurement, forward and reverse energy metering, multi-rate energy statistics, SOE event record; 8-digit LCD display; infrared communication; voltage input maximum 1000V, current external shunt connection (75mV) or Hall element Access (0-5V); power accuracy level 1 |
148 |
1.2DI/2D0(K) |
6 |
|
|
2.The second DC energy metering |
29 |
|
Jiangsu Acrel Electrical Manufacturing Co., LTD. a production base located in Jiangyin City, Wuxi, is a pilot enterprise of Jiangsu Province, which integrates informatization and industrialization. It has a well-functioned product test center, and can carry out environmental, electromagnetic compatibility, safety and reliability tests. The production process relies on advanced information management system and strict implementation of ISO 9001 management standards, which provides guarantee for industrialization and large-scale implementation of products. The annual production capacity of meters, power sensors and energy-saving cabinets is 3.5 million units, 2 million units and 10,000 sets.
Jiangsu acrel Electric is a provider of energy data services for enterprise users to consume energy (electricity, water, gas, or other energy). In combination with the characteristics of enterprise users' energy supply and distribution system, an energy metering system is designed for each user, and a fine and reasonable energy monitoring system is set up. The construction and operation system in the energy supply, reliable reasonable use of energy and electricity safety and other aspects of the user's attention to solve pain points, visual management to help companies achieve energy use data, provide scientific data to support the introduction of the implementation of energy saving measures for enterprises in the future.