Acrel Am3se-I IEC60870-5-103 Overcurrent Protection (50/51) Feeder Transformer Protection Relay 10kv Middle Voltage Relay

Product Details
Customization: Available
Theory: Electromagnetic Relay
Usage: Protection Relay for Medium Voltage Apllication
Still deciding? Get samples of US$ 311.5/Piece
Request Sample
Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Experienced Team
The supplier has 50 foreign trading staff(s) and 25 staff(s) with over 6 years of overseas trading experience
Patents Awarded
The supplier had awarded 1 patents, you can check the Audit Report for more information
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (26)
  • Acrel Am3se-I IEC60870-5-103 Overcurrent Protection (50/51) Feeder Transformer Protection Relay 10kv Middle Voltage Relay
  • Acrel Am3se-I IEC60870-5-103 Overcurrent Protection (50/51) Feeder Transformer Protection Relay 10kv Middle Voltage Relay
  • Acrel Am3se-I IEC60870-5-103 Overcurrent Protection (50/51) Feeder Transformer Protection Relay 10kv Middle Voltage Relay
  • Acrel Am3se-I IEC60870-5-103 Overcurrent Protection (50/51) Feeder Transformer Protection Relay 10kv Middle Voltage Relay
  • Acrel Am3se-I IEC60870-5-103 Overcurrent Protection (50/51) Feeder Transformer Protection Relay 10kv Middle Voltage Relay
  • Acrel Am3se-I IEC60870-5-103 Overcurrent Protection (50/51) Feeder Transformer Protection Relay 10kv Middle Voltage Relay
Find Similar Products
  • Overview
  • General
  • Technical Parametrs
  • Front Panel
  • Wiring
  • LCD Display
  • Dimension
  • Typical Connection
Overview

Basic Info.

Phase
3
Electricity Type
Ac
Load
Medium Power Relay
Protective Characteristics
Enclosed Relay
Action Principle
Electronic Type
Size
Normal Type
Type
Non-Electric Parameter Relay
Product Name
Protection Relay for Medium Voltage Apllication
Brand
OEM ODM
Auxiliary Power Supply
AC/DC 220V AC/DC 110V DC48V
Reference Frequency
45~65Hz
Display Type
LCD
Input Rated Voltage Range
1-120V
Power Consumption
Less Than or Equal to 10W
Rated Current
1A or 5A
Transport Package
Fob Shanghai
Specification
122*165mm
Trademark
ACREL
Origin
China
Production Capacity
100PCS/Per Month

Product Description

General

 

AM series microcomputer protection measurement and control device set protection, measurement, control in one, suitable for 35kV and below the voltage level of the user terminal substation (station), can achieve the protection and measurement and control of the user substation. Application fields cover power, water conservancy, transportation, petroleum, chemical, coal, metallurgy and other industries.
 

Technical Parametrs

Power supply

Rated input

AC/DC220V, or AC/DC110V, or DC48V, or DC24V

Range

Rared Voltage × (1±20%)

Consumption

≤10W (DC)

Rated Voltage

Rated input

AC 100V/100/V

Range

1~120V

Accuracy

±0.5%

Consumption

≤0.5VA (single phase)

Rated Current

Rated input

AC 5A /1A

Range

0.04In~15In

Accuracy

±0.5%

Consumption

≤0.5VA (single phase)

Frequence

Rated frequency

50Hz or 60Hz

Range

45~55Hz or 60Hz

Accuracy

±0.1Hz

DI

Rated Voltage

AC/DC220V, or AC/DC110V, or DC48V, or DC24V

Range

Rared Voltage × (1±20%)

Cconsumption

≤1W (DC220V) (single channel)

DO

Mechanical life

≥10000

Switching capacity

≥1000W, L/R = 40ms

On current

continuous ≥5A, short time (200ms) ≥30A

Interrupting capacity

≥30W, L/R = 40ms

Environment

Temperature

-10ºC~+55ºC

Humidity

5%~95% (No condensation and freeze inside)

Altitude

≤4000m

Front Panel

Acrel Am3se-I IEC60870-5-103 Overcurrent Protection (50/51) Feeder Transformer Protection Relay 10kv Middle Voltage Relay

Wiring

Acrel Am3se-I IEC60870-5-103 Overcurrent Protection (50/51) Feeder Transformer Protection Relay 10kv Middle Voltage Relay

LCD Display

Acrel Am3se-I IEC60870-5-103 Overcurrent Protection (50/51) Feeder Transformer Protection Relay 10kv Middle Voltage Relay

Acrel Am3se-I IEC60870-5-103 Overcurrent Protection (50/51) Feeder Transformer Protection Relay 10kv Middle Voltage Relay
 

Dimension

 

Acrel Am3se-I IEC60870-5-103 Overcurrent Protection (50/51) Feeder Transformer Protection Relay 10kv Middle Voltage Relay

Typical Connection

Acrel Am3se-I IEC60870-5-103 Overcurrent Protection (50/51) Feeder Transformer Protection Relay 10kv Middle Voltage Relay

Types
Acrel Am3se-I IEC60870-5-103 Overcurrent Protection (50/51) Feeder Transformer Protection Relay 10kv Middle Voltage Relay

 


Applicaiton
Acrel Am3se-I IEC60870-5-103 Overcurrent Protection (50/51) Feeder Transformer Protection Relay 10kv Middle Voltage Relay




Acrel Am3se-I IEC60870-5-103 Overcurrent Protection (50/51) Feeder Transformer Protection Relay 10kv Middle Voltage Relay
Acrel Am3se-I IEC60870-5-103 Overcurrent Protection (50/51) Feeder Transformer Protection Relay 10kv Middle Voltage Relay
Acrel Am3se-I IEC60870-5-103 Overcurrent Protection (50/51) Feeder Transformer Protection Relay 10kv Middle Voltage Relay
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier