Acrel Pz72L-De/C Panel Mounted RS485 DC Energy Meter Power Meter

Display: LCD
Installation: Indirect Connected
Usage: Multi-Functional Energy Meter, Watt-Hour Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Reactive Energy Meter
Electric Equipment: Single-phase
Theory: Electronic Meter
Power Meter Connection: Terminal
Samples:
US$ 97.3/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Manufacturer/Factory

360° Virtual Tour

Diamond Member Since 2020

Suppliers with verified business licenses

Jiangsu, China
to see all verified strength labels (26)

Basic Info.

Model NO.
PZ72L-DE/C
Measured Signal
Pulse Peak
Type
Energy Meter
Certification
CE
Customized
Non-Customized
Product Name
Smart Panel Mounted DC Power Meter
Brand
OEM ODM
Input DC Voltage
0~100V,0~500V,0~1000V
Input DC Current
Shunt 75mv or Hall Sensor 0~20mA,0~5V
Optional Function 1
RS485 Modus RTU
Power Consumption
2W
Optional Function 2
Multi Tariff
Optional Function 3
2di/2do
Transport Package
Fob Shanghai
Specification
72*72mm
Trademark
ACREL
Origin
China
HS Code
9028301300
Production Capacity
10000PCS/Per Month

Product Description

Product Description
PZ72L-DE Smart Panel mounted DC Energy Meter

Acrel Pz72L-De/C Panel Mounted RS485 DC Energy Meter Power Meter




General

PZ series intelligent DC energy meter is designed for applications such as DC panels, solar power, telecommunications base stations,and charging posts. This series of instruments can measure voltage, current, power, forward and reverse power in DC system. It can be used for local display, and connected with industrial control equipment, computers, form a measurement and control system. And it has a variety of external excuse functions for the user to choose: RS485 communication interface, Modbus-RTU protocol, relay alarm output, digital input/output. According to different requirements, through the instrument panel keys, you can set the ratio, communication parameters.


Features
 True RMS Measurements
 Unbalance & Phase Angles
 Demands and Multi-Tariff energy
 Max/Min Log with Time stamp
 Alarms and SOE Logs
 External Option module


Types and Functions
Type Basic Function Exterior Optional Function
PZ72L-DE voltage,current,power,energy,LCD desplay 72 square 1.--RS485                                   (/C)
2.--12V power output Δ                   (/V)
3.--RS485 + 2DO                             (/KC)
4.--RS485 + 2DI2DO                          (/KC)
5.--RS485 + 2DO + 12V power output             (/KVC)
6.--RS485 + 12V power output                     (VC)
The above functions can have the following two optional functions at the same time: 
7.--Auxiliary power 20-60V                       (/ZD)
8.--Multiple rate                                  (F)
PZ72-DE voltage,current,power,energy,LCD desplay
Annotation: Δ The functon of 12V power output and DI can not be selected at the same time.

Technical Parameters
Technical Parameters Indicators
Input DC voltage Input range 0~100V,0~500V,0~1000V
Input resistance ≥6kΩ/V
DC current Input range (External Shunt or Hall Current Sensor, the range can be set)
Shunt 75mV
Hall Current Sensor 0~20mA,0~5V
Power consumption ≤1mW
Overload It can work at normal status at 1.2 times of full load, and can contined work 1 second at 2 times of full load.
Accuracy class  0.5class







Function
Measuring Voltage,Current,Power
Calculate Current total electricity,Current positive energy,Current reverse power
Multiple rate Four time zones,two time table,fourteen time points,four multiple rates. (PZ72L-DE support only)
Historical data statistics Last 12 months of historical electricity(multiple rate electricity).(PZ72L-DE support only)
DI,DO 2DI(Collect and display local switch status information,Realize remote transmission by RS485),2DO(Relay output, can achieve "remote control" and alarm output)
Display LCD(the backlight delay time can be adjusted) or LED
Communication RS485,Half duplex,Photoelectric isolation,Modbud-RTU / DL/T645-07,Band:1200/2400/4800/9600,Infrared:1200
DI,DO
 
DI Dry contact input, Meter built-in power supply, photoelectric isolation
DO Two relay outputs, Normally open contact, capacity:2A/30VDC or 2A/250VAC
Working power Voltage range 85~265VAC/DC,50/60Hz;20~60VDC
Power consumption ≤2W
Insulation resistance ≥100MΩ
Power frequency
withstand voltage
3kV/1min(RMS)(between the power supply binding post and the signal binding post)
Environment Temperature Working Temp:-20ºC~+60ºC;Storage Temp:-20ºC~+70ºC
Humidity ≤ 93%RH No condensation, no corrosive gases
Altitude ≤ 2500m

Installation
Acrel Pz72L-De/C Panel Mounted RS485 DC Energy Meter Power Meter








Wiring
Acrel Pz72L-De/C Panel Mounted RS485 DC Energy Meter Power Meter

Acrel Pz72L-De/C Panel Mounted RS485 DC Energy Meter Power Meter

Acrel Pz72L-De/C Panel Mounted RS485 DC Energy Meter Power Meter
Acrel Pz72L-De/C Panel Mounted RS485 DC Energy Meter Power Meter


Acrel Pz72L-De/C Panel Mounted RS485 DC Energy Meter Power Meter

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2020

Suppliers with verified business licenses

Manufacturer/Factory
Registered Capital
166860200 RMB
Plant Area
>2000 square meters