Acrel Akh-0.66p26 Medical Isolation Current Transformer for Hospital Isolated Power System

Product Details
Customization: Available
Classification: Protective Current Transformer
Type: Akh-0.66p26
Still deciding? Get samples of US$ 15.4/Piece
Request Sample

360° Virtual Tour

Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
166860200 RMB
Plant Area
>2000 square meters
  • Acrel Akh-0.66p26 Medical Isolation Current Transformer for Hospital Isolated Power System
  • Acrel Akh-0.66p26 Medical Isolation Current Transformer for Hospital Isolated Power System
  • Acrel Akh-0.66p26 Medical Isolation Current Transformer for Hospital Isolated Power System
  • Acrel Akh-0.66p26 Medical Isolation Current Transformer for Hospital Isolated Power System
  • Acrel Akh-0.66p26 Medical Isolation Current Transformer for Hospital Isolated Power System
Find Similar Products

Basic Info.

Model NO.
AKH-0.66P26
Phase
Single
Rated Frequency
50-60 Hz
Rated Operation Voltage
AC 0.66 Kv
Insulation Strength
3000V/1min 50Hz
Input Current
0.5mA-50A
Output Current
0.025-25mA
Temperature Coefficient
100 Ppm/ºC
Phase Shift
10′
Accurancy
0.5%
Operating Frequency Range
0.02~10kHz
Linearity
0.5%
Trademark
Acrel
Origin
Jiangsu, China

Product Description

Products Description
The AKH-0.66P26 type current transformer is the protective current transformer supporting the AIM-M10 insulation monitor, of which the maximum measurable current is 60A and the transformation ratio is 2000:1. The current transformer is directly fixed inside cabinet by screwing, and the secondary side is leaded out by the terminal, which is convenient to install and use.
 
Acrel Akh-0.66p26 Medical Isolation Current Transformer for Hospital Isolated Power System
Acrel Akh-0.66p26 Medical Isolation Current Transformer for Hospital Isolated Power System
Temperature
Operation:-10ºC~+55ºC                              Storage:-25ºC~+70ºC
Humidity
≤93%RH(No condensation)
Altitude
≤2500m


Technical parameters
Acrel Akh-0.66p26 Medical Isolation Current Transformer for Hospital Isolated Power System

Wiring
Acrel Akh-0.66p26 Medical Isolation Current Transformer for Hospital Isolated Power System

Acrel Akh-0.66p26 Medical Isolation Current Transformer for Hospital Isolated Power SystemAcrel Akh-0.66p26 Medical Isolation Current Transformer for Hospital Isolated Power SystemAcrel Akh-0.66p26 Medical Isolation Current Transformer for Hospital Isolated Power System

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier