Factory Price 3 Phase Adl Series Multifuntion 35mm DIN Rail Power Meter Energy Meter with 485 Communication Adl400/C

Product Details
Customization: Available
Warranty: 2years
Display: LCD
Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Experienced Team
The supplier has 50 foreign trading staff(s) and 25 staff(s) with over 6 years of overseas trading experience
Patents Awarded
The supplier had awarded 1 patents, you can check the Audit Report for more information
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (26)
  • Factory Price 3 Phase Adl Series Multifuntion 35mm DIN Rail Power Meter Energy Meter with 485 Communication Adl400/C
  • Factory Price 3 Phase Adl Series Multifuntion 35mm DIN Rail Power Meter Energy Meter with 485 Communication Adl400/C
  • Factory Price 3 Phase Adl Series Multifuntion 35mm DIN Rail Power Meter Energy Meter with 485 Communication Adl400/C
  • Factory Price 3 Phase Adl Series Multifuntion 35mm DIN Rail Power Meter Energy Meter with 485 Communication Adl400/C
  • Factory Price 3 Phase Adl Series Multifuntion 35mm DIN Rail Power Meter Energy Meter with 485 Communication Adl400/C
  • Factory Price 3 Phase Adl Series Multifuntion 35mm DIN Rail Power Meter Energy Meter with 485 Communication Adl400/C
Find Similar Products

Basic Info.

Model NO.
ADL400/C
Power Meter Connection
Terminal
Measured Signal
Pulse Peak
Type
Energy Meter
Certification
RoHS, ISO, CE
Customized
Non-Customized
Product Name
Three Phase DIN Rail Power Meter
Brand
OEM ODM
Reference Voltage
3*57.7/100V, 3*220/380V, 3*100V, 3*380V
Reference Frequency
45~65Hz
Accuracy
Class 0.5
Maximum
6A,80A
Optional Function 1
RS485 Modus RTU
Optional Function 2
Multi Tafiff
Transport Package
Fob Shanghai
Trademark
ACREL
Origin
China
HS Code
9028301400
Production Capacity
10000PCS/Per Month

Product Description


ADL400 Three Phase Multi-Function Energy Meter
General
Factory Price 3 Phase Adl Series Multifuntion 35mm DIN Rail Power Meter Energy Meter with 485 Communication Adl400/CFactory Price 3 Phase Adl Series Multifuntion 35mm DIN Rail Power Meter Energy Meter with 485 Communication Adl400/C
ADL rail- installation Electricity meters is a new generation electricity meter developed by Acrel Co,.Ltd, resulting from many years experience in designing Electricity meters. LCD display and electricity pulse output function is installed in the power meter; clock, rate period parameters can be set also. Data swap with the super ordination machine via RS485 communication interface greatly facilitate the power automated administration. This power meter has advantages of smaller volume, high precision, good EMC, easy installation etc, meet the related technical requirements of electronic power meter in the IEC62053-21,IEC 62053-22 standard.


Features
Factory Price 3 Phase Adl Series Multifuntion 35mm DIN Rail Power Meter Energy Meter with 485 Communication Adl400/C

 Diverse Electric Parameters Measurement

  kWh (3-phase positive Kilowatt-hours)

  kVarh (Kilovar-hours)

  Harmonic (2~31st voltage&current)---Standard

  U (3-phase Voltage);I (3-phase Current);P (Power);Q  (Reactive   power);F (Frequency);S (Apparent power);PF (Power factor)

 

  Multi-rate/Flexible Tariff

  4 Time zone

  4 Tariff rate (Spike, Peak, Flat, Valley)

  2 Time period list

  14 Time period by day

  Data Frozen (last 48 months or last 90 days)

  Max demand and occurrence time

Factory Price 3 Phase Adl Series Multifuntion 35mm DIN Rail Power Meter Energy Meter with 485 Communication Adl400/C
Factory Price 3 Phase Adl Series Multifuntion 35mm DIN Rail Power Meter Energy Meter with 485 Communication Adl400/C

  HMI for Common Configuration

  PT or CT ratio

  Wiring methods (3P4W or 3P3W)

  Back linght time

  RS485 (MODBUS-RTU) communication setting




Technical Parameters
Specification ADL400 ADL3000-E ADL3000-E/CT  
Voltage Reference voltage 3×100V, 3×380V,3×57.7/100V, 3×220/380V
Consumption <10VA
Impedance >2MΩ      
Accuracy Error±0.2%      
Current Reference current 3×1(6)A,3×10(80)A 3×1(6)A,3×10(80)A  3×1(6)A,3×20(100)A  
Accuracy class Error±0.2%
Consumption <1VA
Power Active, reactive, apparent power, error±0.5℅
Display LCD
Frequency 45~65Hz,Error±0.2%
Option Function Communication RS485, Modbus-RTU compatible protocol
Multi tariff energies Adapt 4 time zones, 2 time interval lists, 14 time interval by day and 4 tariff rates
Harmonic No 2-31st harmonic.  
Switching No 1 Switching output  
NO 1 optocoupler input  
Operation Temperature -25 ºC~+55 ºC
Storage Temperature -25 ºC ~+70 ºC
Altitude ≤ 2500m
Relative humidity ≤95%RH, no condensation, without corrosive gas
 
Dimension(Unit:mm)
Factory Price 3 Phase Adl Series Multifuntion 35mm DIN Rail Power Meter Energy Meter with 485 Communication Adl400/C

Wiring 
1.Direct connect type
Factory Price 3 Phase Adl Series Multifuntion 35mm DIN Rail Power Meter Energy Meter with 485 Communication Adl400/C
Three phase three wire 
Factory Price 3 Phase Adl Series Multifuntion 35mm DIN Rail Power Meter Energy Meter with 485 Communication Adl400/C
Three phase four wire 

2.CT operated type
Factory Price 3 Phase Adl Series Multifuntion 35mm DIN Rail Power Meter Energy Meter with 485 Communication Adl400/C
Three phase three wire
Factory Price 3 Phase Adl Series Multifuntion 35mm DIN Rail Power Meter Energy Meter with 485 Communication Adl400/C
Three phase four wire


Typical connection
Factory Price 3 Phase Adl Series Multifuntion 35mm DIN Rail Power Meter Energy Meter with 485 Communication Adl400/C

FAQ
Q: What's the difference of current input via direct connect or via CTs?
A: Normally, for 3-phase loads with rated current below 80A AC, we will use model of ADL400 whose current input is via direct connect. Specs of "Rated Current: 10(80)A AC" was aimed for this model of ADL400 (current input via direct connect). 10 means basic current is 10A AC, 80 means rated current input is 80A AC.
And for 3-phase loads with rated current over 80A AC, we will use model of ADL400 whose current input is via CTs (usually paired with -/5A CTs whose secondary current output is with 5A AC rated current output). Specs of "Rated Current: 1(6)A AC" was aimed for this model of ADL400 (current input via CTs). 1 means basic current is 1A AC, 6 means max current input is 6A AC.
 
Q: Do your company also have paired CTs for ADL400?
A: Usually, we will recommend our user to use split-core CTs called AKH-0.66/K K-φ Series or solid-core CTs called AKH-0.66/I Series to the paired with ADL400 (current input via CTs)
 
Q: How can I set the CT or PT ratio of ADL400?
A: Current ratio of ADL400 could be set by using the keypads on ADL400 and following the instruction of ADL400 manual. Also, setting need to be according to the CTs or PTs ratio which were paired with ADL400. For example, if the current input is via 250A/5A CTs, the CT ratio on ADL400 should be set to 250/5=50. And if the voltage input is via direct connect, PT ratio on ADL400 should be set to 1. When the problem hasn't been solved, please contact us for help.
 
Q: Could ADL400 be used in IoT Energy Monitoring System for factory or building?
A: ADL400 has standard RS485 interface and MODBUS-RTU communication protocol which allow it to be integrate with our IoT Energy Monitor Solution that can enable our users to remotely check all the data collect by energy meters like ADL400 on their mobile phone or PC. For more information, please Contact us or check in IoT Energy Monitoring Solution Introduction.
 
Q: What is Multi-rate/tariff function? How does it work?
A: First,multi-rate/tariff function was designed to be used for billing system. Second, the electricity price of different time duration in a day is different in some country.
Energy meter with this function can measure the kwh data and assign them to several time duration in a day and put a label of spike/peak/flat/valley kwh on them respectively. And if such energy meter was connected to the billing system by using a IoT gateway, it can send the kwh data of different time duration which was with the label of spike/peak/flat/valley kwh to the billing system for calculating the electricity bill of different time duration in a day.
For example, the electricity price of spike kwh is 5 USD/1 kwh, and time duration of from 9:00 am to 11:30 am was labeled as spike kwh.
Then, if energy meter record 3 kwh used in total during 9:00 am to 11:30 am, it will send the data of 3 kwh with the label of spike kwh to the billing system, and the system calculate the electricity cost of 3x5=15USD in total from 9:00 am to 11:30 am.

Other QuestionPlease contact us and we will get back to you as soon as possible.










 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier