• Acrel Apm520 Ethernet Modbus-TCP Optional 3 Phase Power Analyzer Smart Meter Work with PLC
  • Acrel Apm520 Ethernet Modbus-TCP Optional 3 Phase Power Analyzer Smart Meter Work with PLC
  • Acrel Apm520 Ethernet Modbus-TCP Optional 3 Phase Power Analyzer Smart Meter Work with PLC
  • Acrel Apm520 Ethernet Modbus-TCP Optional 3 Phase Power Analyzer Smart Meter Work with PLC
  • Acrel Apm520 Ethernet Modbus-TCP Optional 3 Phase Power Analyzer Smart Meter Work with PLC
  • Acrel Apm520 Ethernet Modbus-TCP Optional 3 Phase Power Analyzer Smart Meter Work with PLC

Acrel Apm520 Ethernet Modbus-TCP Optional 3 Phase Power Analyzer Smart Meter Work with PLC

After-sales Service: 2 Years
Warranty: 2 Years
Display: Digital
Installation: Indirect Connected
Usage: Multi-Functional Energy Meter, Watt-Hour Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Reactive Energy Meter, Multi-rate Watt-hour Meters, Maximum Demand Meter
Electric Equipment: Three-phase Four-wire
Customization:
Manufacturer/Factory

360° Virtual Tour

Diamond Member Since 2020

Suppliers with verified business licenses

Jiangsu, China
to see all verified strength labels (26)
  • Overview
  • Model Descrption
  • Technical Parameters
  • Main Functions
  • Functions
  • Dimension
  • Wiring
  • Typical Connection
  • Company Profile
Overview

Basic Info.

Model NO.
APM520
Theory
Electronic Meter
Power Meter Connection
Terminal
Measured Signal
Continuous Wave
Type
Energy Meter
Certification
RoHS, ISO, CE
Customized
Customized
Phase
Three Phase
Accuracy
Class 0.5s
Interface
RS485, Ethernet
Protocol
Modbus-RTU,Modbus-RTU/TCP
Voltage
AC 3*57.7/100V, AC 3*63.5/110V, AC 3*230/400V, AC
Transport Package
Carton
Specification
APM
Trademark
ACREL
Origin
China
HS Code
9028301300
Production Capacity
200000

Product Description

Power Quality Monitoring Meter APM520

APM5 series network power meter is designed according to IEC international standards, with full power measurement, power statistics, power quality analysis (including harmonics, interharmonics, flicker), fault recording function (including voltage temporary rise and fall interrupt, inrush current and other records), event recording function and network communication and other functions. It is mainly used for comprehensive monitoring of power supply quality in the power grid.
 

Model Descrption

Acrel Apm520 Ethernet Modbus-TCP Optional 3 Phase Power Analyzer Smart Meter Work with PLC

Acrel Apm520 Ethernet Modbus-TCP Optional 3 Phase Power Analyzer Smart Meter Work with PLC Acrel Apm520 Ethernet Modbus-TCP Optional 3 Phase Power Analyzer Smart Meter Work with PLC Acrel Apm520 Ethernet Modbus-TCP Optional 3 Phase Power Analyzer Smart Meter Work with PLC

Technical Parameters

 
 
Display
Display method
Dot matrix liquid crystal; Switch between Chinese and English
Resolution
128*128;
Backlight
White LED;
Visible area
72 Shape: 38mm*46mm (1.78"/2.3");
96 Shape: 56mm*60mm (2.46"/3.2");
 
 
 
 
 
Signal
Electrical network
Three-phase three-wire, three-phase four-wire, see the wiring diagram;
Frequency
45~65Hz;
 
Voltage
Rating: AC 3*57.7/100V, AC 3*63.5/110V, AC 3*230/400V, AC
3*400/690V (96 Shape only);
Overload: 1.2 times the rating (continuous); 2x rating/1 second;
Power consumption: < 0.5VA(Every way);
 
Current
Ratings: AC 3x 1 (1.2) A, AC 3x5(6)A;
Overload: 1.2 times the rating (continuous); 10x rating/1 second;
Power consumption: < 0.5VA(Every way);
 
 
 
 
Measurement 
accuracy
Voltage, current
EC 61557-12 0.2%
Voltage, current harmonics
IEC 61557-12 1%
Frequency
IEC 61557-12 ±0.02Hz
Active power
IEC 61557-12 0.5%
Reactive power
IEC 61557-12 1%
Active electrical energy
IEC 62053-22 0.5S class (0.2S accuracy when S is selected).
Reactive power
IEC 62053-24 Class 1
Power quality
(only available
when S is selected)
Waves recording
20 waveforms, 10 waves before and after;
Waveform capture
128 cycle points are stored per waveform;
Switch input
Dry contact input, built-in power supply;
Response time: less than 300ms
Relay output
Contact type: normally open contact;
Contact capacity: AC 250V/3A DC 30V/3A;
Energy pulse output
Output mode: photocoupler pulse with open collector;
Pulse constant: 10000imp/kWh (default);
Communication
RS485 interface/Modbus-RTU protocol and DLT645 protocol;
RJ45 interface (Ethernet)/Modbus-TCP protocol;
Wireless interface
Power supply
Working range: AC 85V~265V; DC100V~350V
Power consumption: power consumption≤15VA;
 
 
 
 
 
 
 
Safety
 
 
 
 
 
 
Power frequency
withstand voltage
The power frequency withstand voltage between the housing and the auxiliary powersupply, each input and output terminal group is AC 4kV/1min;
The power frequency withstand voltage between the auxiliary power supply and each input terminal and each output terminal group is AC 2kV/1min;
The power frequency withstand voltage between the voltage input and other input and output terminal blocks is AC 2kV/1min;
The power frequency withstand voltage between the current input and other input and output terminal blocks is AC 2kV/1min;
The power frequency withstand voltage between the relay output and other input and output terminal blocks is AC 2kV/1min;
The power frequency withstand voltage between the terminal groups of switching input, communication, analog output and pulse output is AC 1kV/1min;
Insulation
resistance
Inputs, outputs to the shell>100MΩ;
Electromagnetic compatibility
Complies with IEC 61000 standard (Level 4);
Environment
Operating temperature:-25ºC~+70ºC;Storage temperature:-40ºC~+85ºC;
Relative humidity:≤95% without condensation;Altitude:≤2500m;
Protection level
Display panel IP54; (Optionally IP65).
 
 
 
 
 
 
 
Standards
IEC 60068-2-1
IEC 60068-2-2
IEC 60068-2-30
Environmental Testing-Part 2-1:Tests Test A:Cold IDA
Environmental Testing Part 2-2:Tests Test B:Dry heat
Environmental Testing Part 2-30:Tests Test Db:Damp heat,cyclic (12+12h)
IEC 61000-4
Electromagnetic compatibility-Testing and measurement techniques
IEC 61557-12
Electrical safety in low voltage distribution systems up to 1 000V a.c. and 1500V d.c -Equipment for testing , measuring or monitoring of protective measures - Part12:Performances measuring and monitoring devices(PMD)
IEC 62053-22
Electricity metering equipment (a.c.)-Particular requirements - Part22:Static meter for active energy(class 0.2S and 0.5S)
IEC 62053-24
Electricity metering equipment (a.c.)-Particular requirements - Part24:Static meter for reactive energy at fundamental frequency (classes 0.5S 1S and 1)
  
 

Main Functions

Measured parameters
Total electrical measurement
Four-quadrant energy,Split phase electricity,Apparent energy,Multi-rate energy
Pulse output of energy
Total active, Total reactive energy pulse output (72 type only has active energy pulses)
Demand
Three-phase current, active power, reactive power, real-time demand of apparent power, and maximum demand (including time stamp)
Extreme value statistics
Current, line voltage, phase voltage, active power, reactive power and other electrical
parameters extreme values of this month and last month (including time stamps)
 
 
 
 
 
 
Power quality
Unbalance of current, line voltage, phase voltage
Voltage phase angle, current phase angle
Total (odd, even) harmonic content of voltage and current
Harmonic content of voltage and current (2-63 times)
Interharmonic (included with option S)
Flicker (included with S option)
Voltage peak coefficient
Telephone waveform factor
Current K-factor
Vector
Voltage and current waveform
Fundamental voltage and current
Fault waveform recording
Record of voltage ramp-up and drop interruptions, inrush currents, etc. (included with S option)
Event logging
DIDO records, which can record the last 128 DID records
Alarm logging
The last 128 alarm records can be recorded
Communication
Modbus - RTU protocol, DL/T 645-2007 statute
Switching value
72 Shape: 2 channels of switching input + 2 channels of switching output;
96 Shape: 4 switching inputs + 2 switching outputs

Functions

Base model
Basic function
Optional function
Option Group
 
 
 
 
 
 
 
 
APM520
 
 
 
 
 
 
 
 
4DI2DO,2EP,1C
1. CE (Ethernet Communication/MODBUS-TCP)
 
 
 
 
1+5+6+7+8
2+3+4+7+8
1+5+6+7+8
2+3+4+7+8
5+6+7+8+9
5+6+7+8+10
5+6+7+8+11
5+6+7+8+12
2.2C (Extended 2nd Communication)
3.K (4-way switching input + 2-way switching
output)
4.2M (2ch analog)
5.T (4-channel NTC temperature measurement)
6.L (1 channel leakage)
7.F (Compound Rate)
8.S (0.2S level + fault recording)
9.WF(WiFi Communication)
10.LR(Lora Communication)
11.4G(4G Communication)
12.NB(NB Communication)


 

Dimension



Acrel Apm520 Ethernet Modbus-TCP Optional 3 Phase Power Analyzer Smart Meter Work with PLC

Acrel Apm520 Ethernet Modbus-TCP Optional 3 Phase Power Analyzer Smart Meter Work with PLC

Wiring

Acrel Apm520 Ethernet Modbus-TCP Optional 3 Phase Power Analyzer Smart Meter Work with PLC

 

 

Typical Connection


Acrel Apm520 Ethernet Modbus-TCP Optional 3 Phase Power Analyzer Smart Meter Work with PLC

 

 

Company Profile

Acrel Co., Ltd.[stock code: 300286.SZ] is a high-tech enterprise that integrates R&D, production, sales, and service, since its establishment, is committed to providing users with energy efficiency management and powerful security system solutions. Acrel Electric has a complete production line from cloud platform software to sensors.
Acrel energy efficiency management system including substation operations and maintenance cloud platform, electricity safety management cloud platform, Environmental equipment power consumption monitoring cloud platform, prepaid management (system) cloud platform, intelligent power distribution monitoring system, power quality management system, building energy consumption management system, industrial energy control platform, leakage power monitor and control system, fire-fighting device power monitoring system, fire-proof door monitoring system, emergency lighting and evacuation indicating system, EV charger management system, data center power&environment monitoring system, smart lighting control system, IT isolation power supply system and related products.
The company attaches great importance to product quality and innovation. By the end of 2018, the company has 5 trademarks, 18 invention patents, 72 utility model patents, 94 appearance patents, and 147 computer software Copyrights, and has participated in the formulation of national or industrial standards.
 
Acrel Apm520 Ethernet Modbus-TCP Optional 3 Phase Power Analyzer Smart Meter Work with PLC



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2020

Suppliers with verified business licenses

Manufacturer/Factory
Registered Capital
166860200 RMB
Plant Area
>2000 square meters