• Acrel 300286. Sz Aim-M100 Medical It Insulation Monitoring Device for Hospital It Ungrounded Isolated Power System
  • Acrel 300286. Sz Aim-M100 Medical It Insulation Monitoring Device for Hospital It Ungrounded Isolated Power System
  • Acrel 300286. Sz Aim-M100 Medical It Insulation Monitoring Device for Hospital It Ungrounded Isolated Power System
  • Acrel 300286. Sz Aim-M100 Medical It Insulation Monitoring Device for Hospital It Ungrounded Isolated Power System
  • Acrel 300286. Sz Aim-M100 Medical It Insulation Monitoring Device for Hospital It Ungrounded Isolated Power System

Acrel 300286. Sz Aim-M100 Medical It Insulation Monitoring Device for Hospital It Ungrounded Isolated Power System

Optional Function(1): Double Communication
Optional Function(2): Fault Alarm Output
Optional Function(3): Temperature Monitoring
Optional Function(4): Load Monitoring
Optional Function(5): Centralized Monitoring Software
Optional Function(6): Desconnection Monitoring
Customization:

Contact Supplier

Mrs. Sandra
Application Engineer
Diamond Member Since 2020

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
AIM-M100
Optional Function(7)
Soe Fault Record
Optional Function(8)
Self-Test
Transport Package
Fob Shanghai
Trademark
ACREL
Origin
China
Production Capacity
10000PCS/Per Month

Product Description

Product Description
AIM-M100 Medical Intelligent Insulation Monitor for Medical Insulation System
Acrel 300286. Sz Aim-M100 Medical It Insulation Monitoring Device for Hospital It Ungrounded Isolated Power System


General
Healthcare OT operating theater isolation power systems / IPS for electrical safety Medical insulation monitoring device adopts advanced microcontroller technology, which has high integration, compact size,convenient installation and integrates intelligence, digitalization and networking in one. It is ideal selection for insulation monitoring of isolation power system in Class 2 medical locations such as operating room and intensive care unit.



Features
* real-time monitoring and fault alarming of the ground insulation resistance,
* transformer load current and transformer winding temperature of the monitored IT system,
* be used with insulation fault locator, remotely starting fault-locating and displaying locating results when there are
insulation faults,
* real-time monitor the line disconnection fault, temperature sensor disconnection fault and the functional grounding line
disconnection fault of the monitored system, and give the alarm indication within 2S after the fault occurs,
* relay alarm output, LED alarm indication and other faults indication functions,
* used for centralized alarm and display instrument, test signal generator, insulation fault locator and upper computer management
software communications, and can monitor the operation status of IT system in real time.
* Events logging function, which can record alarm occurrence time and fault type and is convenient for operation personnel to
analyze the operation conditions of system and promptly eliminate the faults.



Technical Parameters
Model AIM-M100
Voltage AC220V( fluctuation range ±10%)
Frequency 50/60Hz
Max power consumption <8VA
Insulation resistance measuring range 10~999kΩ
Relative percentage accuracy 0~±10%
Alarm value range 50~999kΩ
Response time <2S
Measuring voltage <12V
Measuring current <50μA
Measuring range 2.1~50A
Alarm value range 5~50A
Measuring accuracy class 5
Display Digital and percentage display
thermal resistor PT100
Measuring range -50ºC~+200ºC'
Alarm value range 0ºC~+200ºC'
Output type 2 channel relay output(unable to program)
Contact rating AC 250V/3A DC30V/3A
Working temperature -10ºC~+55ºC'
Storage temperature -20ºC+70ºC'
Relative humidity 5%~95%,non-condensing
Altitude ≤2500m
Dimension(Unit:mm)
Acrel 300286. Sz Aim-M100 Medical It Insulation Monitoring Device for Hospital It Ungrounded Isolated Power System
Wiring
Acrel 300286. Sz Aim-M100 Medical It Insulation Monitoring Device for Hospital It Ungrounded Isolated Power System


Typical Connection
Acrel 300286. Sz Aim-M100 Medical It Insulation Monitoring Device for Hospital It Ungrounded Isolated Power System



Certificate
Acrel 300286. Sz Aim-M100 Medical It Insulation Monitoring Device for Hospital It Ungrounded Isolated Power System




Acrel 300286. Sz Aim-M100 Medical It Insulation Monitoring Device for Hospital It Ungrounded Isolated Power System





Acrel 300286. Sz Aim-M100 Medical It Insulation Monitoring Device for Hospital It Ungrounded Isolated Power System


Acrel 300286. Sz Aim-M100 Medical It Insulation Monitoring Device for Hospital It Ungrounded Isolated Power System

Acrel 300286. Sz Aim-M100 Medical It Insulation Monitoring Device for Hospital It Ungrounded Isolated Power System
 

Send your message to this supplier

*From:
*To:
avatar Mrs. Sandra
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now