Customization: | Available |
---|---|
After-sales Service: | 2 Years |
Warranty: | 2 Years |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Power Quality Monitoring Meter APM520
|
Display method
|
Dot matrix liquid crystal; Switch between Chinese and English
|
Resolution
|
128*128;
|
|
Backlight
|
White LED;
|
|
Visible area
|
72 Shape: 38mm*46mm (1.78"/2.3");
96 Shape: 56mm*60mm (2.46"/3.2"); |
|
|
Electrical network
|
Three-phase three-wire, three-phase four-wire, see the wiring diagram;
|
Frequency
|
45~65Hz;
|
|
|
Rating: AC 3*57.7/100V, AC 3*63.5/110V, AC 3*230/400V, AC
3*400/690V (96 Shape only); |
|
Overload: 1.2 times the rating (continuous); 2x rating/1 second;
|
||
Power consumption: < 0.5VA(Every way);
|
||
|
Ratings: AC 3x 1 (1.2) A, AC 3x5(6)A;
|
|
Overload: 1.2 times the rating (continuous); 10x rating/1 second;
|
||
Power consumption: < 0.5VA(Every way);
|
||
accuracy
|
Voltage, current
|
EC 61557-12 0.2%
|
Voltage, current harmonics
|
IEC 61557-12 1%
|
|
Frequency
|
IEC 61557-12 ±0.02Hz
|
|
Active power
|
IEC 61557-12 0.5%
|
|
Reactive power
|
IEC 61557-12 1%
|
|
Active electrical energy
|
IEC 62053-22 0.5S class (0.2S accuracy when S is selected).
|
|
Reactive power
|
IEC 62053-24 Class 1
|
|
Power quality
(only available when S is selected) |
Waves recording
|
20 waveforms, 10 waves before and after;
|
Waveform capture
|
128 cycle points are stored per waveform;
|
|
Switch input
|
Dry contact input, built-in power supply;
Response time: less than 300ms |
|
Relay output
|
Contact type: normally open contact;
Contact capacity: AC 250V/3A DC 30V/3A; |
|
Energy pulse output
|
Output mode: photocoupler pulse with open collector;
Pulse constant: 10000imp/kWh (default); |
|
Communication
|
RS485 interface/Modbus-RTU protocol and DLT645 protocol;
RJ45 interface (Ethernet)/Modbus-TCP protocol; Wireless interface |
|
Power supply
|
Working range: AC 85V~265V; DC100V~350V
Power consumption: power consumption≤15VA; |
|
|
withstand voltage |
The power frequency withstand voltage between the housing and the auxiliary powersupply, each input and output terminal group is AC 4kV/1min;
The power frequency withstand voltage between the auxiliary power supply and each input terminal and each output terminal group is AC 2kV/1min; The power frequency withstand voltage between the voltage input and other input and output terminal blocks is AC 2kV/1min; The power frequency withstand voltage between the current input and other input and output terminal blocks is AC 2kV/1min; The power frequency withstand voltage between the relay output and other input and output terminal blocks is AC 2kV/1min; The power frequency withstand voltage between the terminal groups of switching input, communication, analog output and pulse output is AC 1kV/1min; |
Insulation
resistance |
Inputs, outputs to the shell>100MΩ;
|
|
Electromagnetic compatibility
|
Complies with IEC 61000 standard (Level 4);
|
|
Environment
|
Operating temperature:-25ºC~+70ºC;Storage temperature:-40ºC~+85ºC;
Relative humidity:≤95% without condensation;Altitude:≤2500m; |
|
Protection level
|
Display panel IP54; (Optionally IP65).
|
|
|
IEC 60068-2-1
IEC 60068-2-2 IEC 60068-2-30 |
Environmental Testing-Part 2-1:Tests Test A:Cold IDA
Environmental Testing Part 2-2:Tests Test B:Dry heat Environmental Testing Part 2-30:Tests Test Db:Damp heat,cyclic (12+12h) |
IEC 61000-4
|
Electromagnetic compatibility-Testing and measurement techniques
|
|
IEC 61557-12
|
Electrical safety in low voltage distribution systems up to 1 000V a.c. and 1500V d.c -Equipment for testing , measuring or monitoring of protective measures - Part12:Performances measuring and monitoring devices(PMD)
|
|
IEC 62053-22
|
Electricity metering equipment (a.c.)-Particular requirements - Part22:Static meter for active energy(class 0.2S and 0.5S)
|
|
IEC 62053-24
|
Electricity metering equipment (a.c.)-Particular requirements - Part24:Static meter for reactive energy at fundamental frequency (classes 0.5S 1S and 1)
|
Measured parameters
|
Total electrical measurement
|
Four-quadrant energy,Split phase electricity,Apparent energy,Multi-rate energy
|
|
Pulse output of energy
|
Total active, Total reactive energy pulse output (72 type only has active energy pulses)
|
Demand
|
Three-phase current, active power, reactive power, real-time demand of apparent power, and maximum demand (including time stamp)
|
Extreme value statistics
|
Current, line voltage, phase voltage, active power, reactive power and other electrical
parameters extreme values of this month and last month (including time stamps) |
|
Unbalance of current, line voltage, phase voltage
|
Voltage phase angle, current phase angle
|
|
Total (odd, even) harmonic content of voltage and current
|
|
Harmonic content of voltage and current (2-63 times)
|
|
Interharmonic (included with option S)
|
|
Flicker (included with S option)
|
|
Voltage peak coefficient
|
|
Telephone waveform factor
|
|
Current K-factor
|
|
Vector
|
|
Voltage and current waveform
|
|
Fundamental voltage and current
|
|
Fault waveform recording
|
Record of voltage ramp-up and drop interruptions, inrush currents, etc. (included with S option)
|
Event logging
|
DIDO records, which can record the last 128 DID records
|
Alarm logging
|
The last 128 alarm records can be recorded
|
Communication
|
Modbus - RTU protocol, DL/T 645-2007 statute
|
Switching value
|
72 Shape: 2 channels of switching input + 2 channels of switching output;
96 Shape: 4 switching inputs + 2 switching outputs |
Base model
|
Basic function
|
Optional function
|
Option Group
|
APM520
|
4DI2DO,2EP,1C
|
1. CE (Ethernet Communication/MODBUS-TCP)
|
1+5+6+7+8
2+3+4+7+8 1+5+6+7+8 2+3+4+7+8 5+6+7+8+9 5+6+7+8+10 5+6+7+8+11 5+6+7+8+12 |
2.2C (Extended 2nd Communication)
|
|||
3.K (4-way switching input + 2-way switching
output) |
|||
4.2M (2ch analog)
|
|||
5.T (4-channel NTC temperature measurement)
|
|||
6.L (1 channel leakage)
|
|||
7.F (Compound Rate)
|
|||
8.S (0.2S level + fault recording)
|
|||
9.WF(WiFi Communication)
|
|||
10.LR(Lora Communication)
|
|||
11.4G(4G Communication)
|
|||
12.NB(NB Communication)
|