• Acrel Amc16z-Fak24 24 Channels AC Energy Meter Designed for The Data Center with RS485 and 2ND-31st Harmonic for Data Center
  • Acrel Amc16z-Fak24 24 Channels AC Energy Meter Designed for The Data Center with RS485 and 2ND-31st Harmonic for Data Center
  • Acrel Amc16z-Fak24 24 Channels AC Energy Meter Designed for The Data Center with RS485 and 2ND-31st Harmonic for Data Center
  • Acrel Amc16z-Fak24 24 Channels AC Energy Meter Designed for The Data Center with RS485 and 2ND-31st Harmonic for Data Center
  • Acrel Amc16z-Fak24 24 Channels AC Energy Meter Designed for The Data Center with RS485 and 2ND-31st Harmonic for Data Center
  • Acrel Amc16z-Fak24 24 Channels AC Energy Meter Designed for The Data Center with RS485 and 2ND-31st Harmonic for Data Center

Acrel Amc16z-Fak24 24 Channels AC Energy Meter Designed for The Data Center with RS485 and 2ND-31st Harmonic for Data Center

Warranty: 2years
Display: Digital
Installation: Indirect Connected
Usage: Multi-Functional Energy Meter, Watt-Hour Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Reactive Energy Meter
Electric Equipment: Three-phase Three-wire
Theory: Electronic Meter
Samples:
US$ 125/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2020

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
AMC16Z-FAK24
Power Meter Connection
Terminal
Measured Signal
Pulse Peak
Type
Energy Meter
Certification
RoHS, ISO, CE
Customized
Non-Customized
Product Name
Data Center Monitoring Power Meter
Brand
OEM ODM
Auxiliary Power Supply
DC12V
Reference Frequency
45~60Hz
Accuracy
Class 2
Current Via CT
Xxa/50mA
Communication
RS485 Modus RTU
Installtion Type
DIN Rail Mounting Energy Meter
Rated Voltage
3*220V/380V
Transport Package
Fob Shanghai
Specification
180*94.3*75mm
Trademark
ACREL
Origin
China
HS Code
9028301400
Production Capacity
10000PCS/Per Month

Product Description

Product Description
AMC16Z-FAK24 Data Center Monitoring Power Meter
General

With the rapid development of data center, the energy consumption problems about the data center have become increasingly serious, and energy management and the design of power supply and distribution have become hot problems; efficient and reliable power distribution system scheme for data center is an effective method to improve the power utilization efficiency of the data center and reduce the energy consumption of equipment. In order to achieve the energy conservation of data center, firstly it is necessary to accurately monitor each electricity load, but there are many loading circuits in the data center, and the traditional measuring instruments are incapable of satisfying the requirements for cost, volume, installation, construction and the like; hence, it is necessary to apply multi-circuit monitoring device applicable to the centralized monitoring requirements of data center. 
AMC16 series multi-circuit monitoring device of Acrel Company is a measuring device designed
specifically for the power supply management of server in the data center. Such device is small and exquisite in design, capable of centralized monitoring on various electric parameters and on-off states of dozens of circuits, including incoming line circuit and outgoing line circuit, and it achieves the highly integration of monitoring circuits in volume.


Features

* 24 channels of each circuit of A+B
* independent 2 circuits the outgoing current,
* active power, active power, reactive power
* 2-31st harmonic, 24DI

Acrel Amc16z-Fak24 24 Channels AC Energy Meter Designed for The Data Center with RS485 and 2ND-31st Harmonic for Data Center

* 1 RS485 communication
* Installation:DIN rail 35mm *Dimension(L*W*H):180*94.3*75mm * Frequency:45~60Hz * Current input: 50mA * Rated voltage: 220VAC

Acrel Amc16z-Fak24 24 Channels AC Energy Meter Designed for The Data Center with RS485 and 2ND-31st Harmonic for Data Center



Technical Parameters
Technical parameters AMC16Z-FAK24 AMC16Z-FAK48
Measurement parameters Voltage, current, frequency, active power, reactive power, power factor, active power, reactive power, switching state
2-31 times harmonics
Bus Voltage Rated 220VAC
Measurement ±20%
Overload Instantaneous voltage 2 times/second
Current outgoing line
loop
Rated 50mA
Range 0.125~60mA
 Overload   Duration 1.2 times, instantaneous 10 times/second 
 Input frequency   45~60Hz 
 Measurement accuracy   Outgoing line   Voltage/current/active power/active energy level 0.5, reactive power/reactive energy level 1 
 Auxiliary power supply   Power supply by AMC16Z-ZA 
 Environment   Temperature   Working:-15ºC~55ºC Storage:-25ºC~70ºC 
 Humidity   Relative humidity 
 Altitude   ≤2500m 
 Communication   RS485/Modbus-RTU 
 Installation method   DIN35mm Guide rail or bottom plate mounting 
 IP grade   IP20 
 Class of pollution   2 
 Safe   Insulation   All terminals and the insulation resistance between the conductive pieces not below 100 m Ω 
 Withstand voltage   A-channel voltage and current signal // B-channel voltage and current signal // other ports meet AC2kV 1min between pairs, leakage current should be less than 2mA, no breakdown or flashover phenomenon. 
 Electromagnetic compatibility   Anti static interference   Level 4 
 Resistance to radiation of Radio frequency electromagneti   Level 3 



Wiring

Acrel Amc16z-Fak24 24 Channels AC Energy Meter Designed for The Data Center with RS485 and 2ND-31st Harmonic for Data Center



Typical connection

Acrel Amc16z-Fak24 24 Channels AC Energy Meter Designed for The Data Center with RS485 and 2ND-31st Harmonic for Data Center
Acrel Amc16z-Fak24 24 Channels AC Energy Meter Designed for The Data Center with RS485 and 2ND-31st Harmonic for Data Center Acrel Amc16z-Fak24 24 Channels AC Energy Meter Designed for The Data Center with RS485 and 2ND-31st Harmonic for Data Center





Quotation
Shape Model Function FOB Shanghai
(USD)
Option function and price(USD)
Acrel Amc16z-Fak24 24 Channels AC Energy Meter Designed for The Data Center with RS485 and 2ND-31st Harmonic for Data Center AMC16Z-ZA Monitor the full power parameters of A+B double-way three-phase AC incoming circuit, Neutral ground voltage, neutral current,6-way switch state monitoring, 2-way alarm output, 2-way leakage communication, and phase-sequence detection. 130 1.Temp & Humidity sensor
2.Leakage current trandformer
AMC16Z-ZD Monitor the full power parameters of 24 branches of A+B double-way AC outgoing line, 1-way RS485 communication and phase adjustment. 118 Temp & Humidity sensor
AMC16Z-KA Wet contact, monitoring A+B total 48 branch switch state, 1-way RS485 communication. 88 /
AMC16Z-KD Dry contact, monitoring A+B total 48 branch switch state, 1-way RS485 communication. 88 /
Acrel Amc16z-Fak24 24 Channels AC Energy Meter Designed for The Data Center with RS485 and 2ND-31st Harmonic for Data Center AMC16Z-FAK24  Monitor the full power parameters and switch state of 24 branches of A+B double way AC outgoing line, 1-way RS485 communication and phase adjustment. 175 /
AMC16Z-FAK48 Monitor the full power parameters and switch state of 48 branches of A+B double way AC outgoing line, 1-way RS485 communication and phase adjustment. 266 /
AMC16Z-FDK24 Monitor the full-power parameters and switching status of A+B double-channel DC outlet 24and 1-channel RS485 communication. 175 /
AMC16Z-FDK48 Monitor the full-power parameters and switching status of A+B double-channel DC off-line 48 sub-lines and 1-channel RS485 communication. 266 /
Acrel Amc16z-Fak24 24 Channels AC Energy Meter Designed for The Data Center with RS485 and 2ND-31st Harmonic for Data Center AMC16Z-D Monitor the full power parameters of three-phase incoming circuit,Neutral ground voltage, neutral current, 4-way switch state monitoring, 2-way alarm output, 2-way leakage communication,Full power parameters of 21-way single-phase outgoing lines (7-way three-phase) 266 1.Temperature monitoring(T)+30
2.Temperature sensor+8
3.Leakage monitoring(L)+30
4.Harmonic and demand measurement(H)+30

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2020

Suppliers with verified business licenses

Manufacturer/Factory
Registered Capital
166860200 RMB
Plant Area
>2000 square meters