• Multi-Channel Electricity Power Energy Meter in Panel Supply Data Center IDC Dcim From UPS Environment Temp. and Pue Power Usage Effectiveness Monitor System
  • Multi-Channel Electricity Power Energy Meter in Panel Supply Data Center IDC Dcim From UPS Environment Temp. and Pue Power Usage Effectiveness Monitor System
  • Multi-Channel Electricity Power Energy Meter in Panel Supply Data Center IDC Dcim From UPS Environment Temp. and Pue Power Usage Effectiveness Monitor System
  • Multi-Channel Electricity Power Energy Meter in Panel Supply Data Center IDC Dcim From UPS Environment Temp. and Pue Power Usage Effectiveness Monitor System
  • Multi-Channel Electricity Power Energy Meter in Panel Supply Data Center IDC Dcim From UPS Environment Temp. and Pue Power Usage Effectiveness Monitor System
  • Multi-Channel Electricity Power Energy Meter in Panel Supply Data Center IDC Dcim From UPS Environment Temp. and Pue Power Usage Effectiveness Monitor System

Multi-Channel Electricity Power Energy Meter in Panel Supply Data Center IDC Dcim From UPS Environment Temp. and Pue Power Usage Effectiveness Monitor System

Warranty: 2years
Display: Digital
Installation: Indirect Connected
Usage: Multi-Functional Energy Meter, Watt-Hour Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Reactive Energy Meter
Electric Equipment: Three-phase Four-wire
Theory: Electronic Meter
Samples:
US$ 99/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Manufacturer/Factory

360° Virtual Tour

Diamond Member Since 2020

Suppliers with verified business licenses

Jiangsu, China
to see all verified strength labels (26)
  • Overview
  • Structure
  • Networking
  • Product Description
  • Function
  • Human Machine Interface
  • Related Products
  • Company Profile
Overview

Basic Info.

Model NO.
AMC16Z Series meter
Power Meter Connection
Terminal
Measured Signal
Pulse Peak
Type
Energy Meter
Certification
RoHS, ISO, CE
Customized
Non-Customized
Product Name
Data Center Monitoring Power Meter
Brand
OEM ODM
Auxiliary Power Supply
AC85~265V/DC100-350V
Reference Frequency
45~60Hz
Accuracy
Class 0.2(U/I) Class 0.5(P/Ep)
Current Via CT
Xxa/5A
Communication
RS485 Modus RTU
Installtion Type
DIN Rail Mounting Energy Meter
Rated Voltage
220V
Voltage Range
40-400V AC
Transport Package
Fob Shanghai
Specification
180*94.3*45mm
Trademark
ACREL
Origin
China
Production Capacity
10000PCS/Per Month

Product Description

Product Description

Multi-Channel Energy Meter for Data Center IDC DCIM PUE Power Usage Effectiveness Monitor System

Structure

Multi-Channel Electricity Power Energy Meter in Panel Supply Data Center IDC Dcim From UPS Environment Temp. and Pue Power Usage Effectiveness Monitor SystemMulti-Channel Electricity Power Energy Meter in Panel Supply Data Center IDC Dcim From UPS Environment Temp. and Pue Power Usage Effectiveness Monitor System

Networking

Multi-Channel Electricity Power Energy Meter in Panel Supply Data Center IDC Dcim From UPS Environment Temp. and Pue Power Usage Effectiveness Monitor System

Product Description

With the rapid development of data centers, the energy consumption of data centers has become more and more prominent, and the energy management and power supply and distribution design of data centers have become hot issues.
An efficient and reliable data center power distribution system solution is an effective way to improve the Power Usage Effectiveness (PUE) of the data center and reduce the energy consumption of equipment.
The AMC series precision power distribution monitoring solution is a complete solution designed for the power distribution monitoring requirements of the column head cabinet in the Internet Data Center (IDC).

It is necessary to real-time monitor and centralizes power consumption in the data center and data can be displayed on HMI, and uploaded to the power and environment monitoring system by RS485 on the touch screen and realize real-time monitoring of the whole power distribution system. At the same time, it can realize energy efficiency analysis to reduce energy consumption.

Function

1) Incoming line and outgoing line circuits independent monitoring modules;

2) Can measure up to 2 incoming line circuits and up to 192 outgoing line circuits current, voltage, power, energy, and power quality;

3) Data centralized monitoring and display by HMI and data is uploaded to power and environment monitoring system through RS485;

4) For high voltage DC 240V or 336V system, an insulation monitoring module can be added to monitor the ground insulation resistance of the main bus;

5) DC24V power supply for touch screen and outgoing line monitoring module(power supply from main module output );

6) Communication: monitoring device by RS485, touch screen by RS485 or RJ45;

7) Certificate: CE.

 

 

Human Machine Interface

Website:  http://116.236.149.165:8090/DataCenter/login
Account:  guest
Password:  123456

Multi-Channel Electricity Power Energy Meter in Panel Supply Data Center IDC Dcim From UPS Environment Temp. and Pue Power Usage Effectiveness Monitor System

Related Products

Product Name Image Function
AMC16Z-ZA Data Center Monitor Device Multi-Channel Electricity Power Energy Meter in Panel Supply Data Center IDC Dcim From UPS Environment Temp. and Pue Power Usage Effectiveness Monitor System

☆ Designed specifically for the power supply management of server in the data center

★ A+B independent 2 channels three-phase inlet

☆ U, I, P, Q, S, PF, kWh, kvarh

★ 2nd-63rd  Harmonic

AMC16Z-FAK48 Data Center Monitor Device Multi-Channel Electricity Power Energy Meter in Panel Supply Data Center IDC Dcim From UPS Environment Temp. and Pue Power Usage Effectiveness Monitor System

☆ Designed specifically for the power supply management of server in the data center

★ A+B independent 24 circuits(48 in total)

☆ U, I, P, Q, S, PF, kWh, kvarh

★ 2nd-31st  Harmonic

☆ kWh Class 0.5

DIN 35 mm

AMC16Z-ZD DC Incoming Line Monitoring Module Multi-Channel Electricity Power Energy Meter in Panel Supply Data Center IDC Dcim From UPS Environment Temp. and Pue Power Usage Effectiveness Monitor System

☆ DIN 35mm

★ Measurement: A+B independent circuits, 6DI 2DO,1 temp. and humidity.

☆ With DC 24V output power supply for outgoing line module and touch screen.

★ Communication: RS485 Modbus RTU

AMC16Z-FDK24/48 DC Outgoing Line Monitoring Module Multi-Channel Electricity Power Energy Meter in Panel Supply Data Center IDC Dcim From UPS Environment Temp. and Pue Power Usage Effectiveness Monitor System

☆ DIN 35mm

★ Can measure up to 48 circuits DC outgoing line

☆ DC24V power supply

★ Communication: RS485 Modbus RTU

AMC16Z-ZJY DC Incoming Line Insulation Monitoring Module Multi-Channel Electricity Power Energy Meter in Panel Supply Data Center IDC Dcim From UPS Environment Temp. and Pue Power Usage Effectiveness Monitor System

☆ DIN 35mm

★ Measure A+B independent DC circuit ground insulation resistance of the main bus

☆ DC24V power supply

★ Communication: RS485 Modbus RTU

AKH-0.66WAB Current Sensor Multi-Channel Electricity Power Energy Meter in Panel Supply Data Center IDC Dcim From UPS Environment Temp. and Pue Power Usage Effectiveness Monitor System ☆ Current Ratio: 50A/50mA & 100A/50mA
★ Accuracy: 0.2 grade
☆ Load: 10 VA/Ω
★ Inner Aperture: 9mm & 15mm
☆ Installation: Din-rail
AKH-EMS Multi-Channel Electricity Power Energy Meter in Panel Supply Data Center IDC Dcim From UPS Environment Temp. and Pue Power Usage Effectiveness Monitor System ☆ Current Ratio: 50A/10mA
★ Accuracy: 0.2 grade
☆ Load: 10 VA/Ω
★ Installation: Din-rail

 

Company Profile

Acrel Co., Ltd.[stock code: 300286.SZ] is a high-tech enterprise that integrates R&D, production, sales, and service, since its establishment, is committed to providing users with energy efficiency management and powerful security system solutions. Acrel Electric has a complete production line from cloud platform software to sensors.
Acrel energy efficiency management system including substation operations and maintenance cloud platform, electricity safety management cloud platform, Environmental equipment power consumption monitoring cloud platform, prepaid management (system) cloud platform, intelligent power distribution monitoring system, power quality management system, building energy consumption management system, industrial energy control platform, leakage power monitor and control system, fire-fighting device power monitoring system, fire-proof door monitoring system, emergency lighting and evacuation indicating system, EV charger management system, data center power&environment monitoring system, smart lighting control system, IT isolation power supply system and related products.
The company attaches great importance to product quality and innovation. By the end of 2018, the company has 5 trademarks, 18 invention patents, 72 utility model patents, 94 appearance patents, and 147 computer software Copyrights, and has participated in the formulation of national or industrial standards.
Multi-Channel Electricity Power Energy Meter in Panel Supply Data Center IDC Dcim From UPS Environment Temp. and Pue Power Usage Effectiveness Monitor System

 


Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2020

Suppliers with verified business licenses

Manufacturer/Factory
Registered Capital
166860200 RMB
Plant Area
>2000 square meters