Acrel Amc16mA Multi Circuit Multi-Channel Power Monitoring Meter with RS485 Modbus Energy Meter for Data Center

Display: LCD
Installation: Indirect Connected
Usage: Multi-Functional Energy Meter, Watt-Hour Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Reactive Energy Meter
Electric Equipment: Three-phase Three-wire
Theory: Electronic Meter
Power Meter Connection: Terminal
Samples:
US$ 122.5/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2020

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
AMC16MA
Measured Signal
Pulse Peak
Type
Energy Meter
Certification
RoHS, ISO, CE
Customized
Non-Customized
Product Name
Data Center Monitoring Power Meter
Brand
OEM ODM
Auxiliary Power Supply
220V AC/240V DC
Reference Frequency
45~60Hz
Warranty
2years
Accuracy
Class 1
Rated Current
0-10A
Communication
RS485 Modus RTU
Installtion Type
DIN Rail Mounting Energy Meter
Transport Package
Fob Shanghai
Specification
194*128*88mm
Trademark
ACREL
Origin
China
HS Code
9028301400
Production Capacity
10000PCS/Per Month

Product Description

Product Description
AMC16MA Data Center Monitor Device
General

With the rapid development of data center, the energy consumption problems about the data center have become increasingly serious, and energy management and the design of power supply and distribution have become hot problems; efficient and reliable power distribution system scheme for data center is an effective method to improve the power utilization efficiency of the data center and reduce the energy consumption of equipment. In order to achieve the energy conservation of data center, firstly it is necessary to accurately monitor each electricity load, but there are many loading circuits in the data center, and the traditional measuring instruments are incapable of satisfying the requirements for cost, volume, installation, construction and the like; hence, it is necessary to apply multi-circuit monitoring device applicable to the centralized monitoring requirements of data center. 
AMC16 series multi-circuit monitoring device of Acrel Company is a measuring device designed
specifically for the power supply management of server in the data center. Such device is small and exquisite in design, capable of centralized monitoring on various electric parameters and on-off states of dozens of circuits, including incoming line circuit and outgoing line circuit, and it achieves the highly integration of monitoring circuits in volume.


Features
Designed specifically for the power supply management of server in the data center
 Including 2 incoming line circuit and 36 outgoing line circuit
U, I, P, Q, S, PF, kWh, kvarh
 Optional 2nd-15th harmonic
Communication:RS485 (Modbus-RTU)
2 channels inlet,36 channels outlet
Rated U and I:AC 220/380V


Technical Parameters
Acrel Amc16mA Multi Circuit Multi-Channel Power Monitoring Meter with RS485 Modbus Energy Meter for Data Center



Function
Acrel Amc16mA Multi Circuit Multi-Channel Power Monitoring Meter with RS485 Modbus Energy Meter for Data Center
Acrel Amc16mA Multi Circuit Multi-Channel Power Monitoring Meter with RS485 Modbus Energy Meter for Data Center






Wiring
Acrel Amc16mA Multi Circuit Multi-Channel Power Monitoring Meter with RS485 Modbus Energy Meter for Data Center



Typical connection

Acrel Amc16mA Multi Circuit Multi-Channel Power Monitoring Meter with RS485 Modbus Energy Meter for Data Center
Quotation

Acrel Amc16mA Multi Circuit Multi-Channel Power Monitoring Meter with RS485 Modbus Energy Meter for Data Center
Acrel Amc16mA Multi Circuit Multi-Channel Power Monitoring Meter with RS485 Modbus Energy Meter for Data Center


Acrel Amc16mA Multi Circuit Multi-Channel Power Monitoring Meter with RS485 Modbus Energy Meter for Data Center
Acrel Amc16mA Multi Circuit Multi-Channel Power Monitoring Meter with RS485 Modbus Energy Meter for Data Center
Acrel Amc16mA Multi Circuit Multi-Channel Power Monitoring Meter with RS485 Modbus Energy Meter for Data Center
Acrel Amc16mA Multi Circuit Multi-Channel Power Monitoring Meter with RS485 Modbus Energy Meter for Data Center

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2020

Suppliers with verified business licenses

Manufacturer/Factory
Registered Capital
166860200 RMB
Plant Area
>2000 square meters