Jiangsu, China
Business Type:
Manufacturer/Factory
Registered Capital:
166860200 RMB
Plant Area:
>2000 square meters
Management System Certification:
ISO 9001
Average Lead Time:
Peak season lead time: within 15 workdays
Off season lead time: within 15 workdays
OEM/ODM Service
Sample Available

Base Station Data Monitoring Meter, DC Energy Meter for Base Transceiver Station, DC Power Meter for Base Transceiver Station manufacturer / supplier in China, offering Acrel Amc16-Dett 6 Channel / 6 Circuit DC Energy Power Meter for Base Transceiver Station, Acrel 0.66 Kv Low Voltage Toroidal Split Core Current Transformer for Renovation Project Reconstruction Projects with Ce Certificate Akh-0.66-K-24 300/5A, Acrel LCD AC Programmable Optional Switching Input/ Output Voltmeter Voltage Meter Amc72L-AV3 and so on.

Diamond Member Since 2020
Audited Supplier
Supplier Homepage Products Power Monitoring and Protection > Data Centre Monitor Device Acrel Amc16-Dett 6 Channel / 6 Circuit DC Energy Power Meter for Base Transceiver Station

Acrel Amc16-Dett 6 Channel / 6 Circuit DC Energy Power Meter for Base Transceiver Station

Min. Order / Reference FOB Price
1 Piece US $62/ Piece
Port: Shanghai, China
Production Capacity: 10000PCS/Per Month
Payment Terms: T/T
Display: Digital
Installation: Indirect Connected
Usage: Meter for Industry and Home Use, Reactive Energy Meter, Base Station Energy Meter
Electric Equipment: Single-phase
Theory: Electronic Meter
Power Meter Connection: Terminal

You Might Also Like

Loading...

Basic Info.

Model NO.
AMC16-DETT
Measured Signal
Pulse Peak
Type
Energy Meter
Certification
RoHS, ISO, CE
Customized
Non-Customized
Product Name
Base Station Power Meter
Brand
OEM ODM
DC Rated Voltage
1 Channel: -48VDC
Warranty
2years
Hall Sensor Power Supply
Power Supply Output:+12V/100mA, -12V/50mA
AuxiliaryTpower Supply
-40V~-60VDC
Protection Level
IP20
Trademark
ACREL
Transport Package
Fob Shanghai
Specification
89.7*87.8*52mm
Origin
China
HS Code
9028301300
Product Description
AMC16-DETT Base Station DC Energy Meter
General

Base station dedicated DC energy meter AMC16-DETT is specially designed for base stations where have sharing requirements, and switch power supply is without the function of sub-user metering. The meter could measure 6 circuits DC energy, and supply working current to the matched hall sensors. Meanwhile, it can realize zero drift calibration by upper computer software. have the functions of telemetering,teleindication,teleadjusting, metering at real time, energy quality abnormal alarm, data storage and processing, data interaction. This meter can measure  DC power consumption of three operators, providing detail datas for base station.

Features
1.DC rated voltage: 1 channel: -48VDC
2.Accuracy:1%In≤I≤10%In error±2.5%; I>10%In error±2%
3.RS485(MODBUS-RTU)
4.LED display
5.DIN 35 mm
6.Rated U and I:Total 200A/5V


Technical Parameters
Technical parameterIndex





input
DC rated voltage1 channel: -48VDC

DC current
6 channels hall sensors: total 200A/5V, China Telecom, China Mobile, China Unicom and the 1st channel reserve 50A/5V, 2nd
channel reserve 100A/5V.
Commercial power
monitoring

1 channel: 0-5VDC

Overload capacity
Voltage:1.2times continued,2 times continued 1s;
Current: 1.2 times continued,10 times continued 1s.
Accuracy (superposition hall sensors)1%In≤I≤10%In error±2.5%; I>10%In error±2%

Measurement resolution
Voltage output accuracy 0.01V;    current output accuracy 0.01A;
power output accuracy 0.01kw; energy output accuracy 0.01kwh









functions

Basic function
Monitor device system time, total voltage, output total current, power, energy, each channel voltage, current, power, energy; LED
indicator display;485 communication




Metering function
Start current: under rated voltage, when the load current value of the meter doesn't exceed 1% of the max. current, the meter starts.
Shunt running current: when there is no current in the current circuit of the meter, and 85%-125%of the rated voltage is applied on the voltage circuit, the calculator shall not have more than
one digital change


Alarm function
DC voltage output low alarm,DC voltage output high alarm,one power down alarm, module voltage loss alarm, metering branch error alarm, internal program error alarm, clock error alarm,
memory failure alarm, AC input power failure alarm

Function

Acrel Amc16-Dett 6 Channel / 6 Circuit DC Energy Power Meter for Base Transceiver Station

Acrel Amc16-Dett 6 Channel / 6 Circuit DC Energy Power Meter for Base Transceiver Station

Dimension
Acrel Amc16-Dett 6 Channel / 6 Circuit DC Energy Power Meter for Base Transceiver StationWiring

Acrel Amc16-Dett 6 Channel / 6 Circuit DC Energy Power Meter for Base Transceiver StationQuotation

Acrel Amc16-Dett 6 Channel / 6 Circuit DC Energy Power Meter for Base Transceiver Station



Acrel Amc16-Dett 6 Channel / 6 Circuit DC Energy Power Meter for Base Transceiver Station
Acrel Amc16-Dett 6 Channel / 6 Circuit DC Energy Power Meter for Base Transceiver Station
Acrel Amc16-Dett 6 Channel / 6 Circuit DC Energy Power Meter for Base Transceiver Station
Acrel Amc16-Dett 6 Channel / 6 Circuit DC Energy Power Meter for Base Transceiver Station

Send your message to this supplier

*From:
*To:
avatar Mrs. Sandra
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now